Equipment Contract Secification Qualification Program Plan (QPP) 1319-01647-46-4 PRESELECTOR LRI
Para Title Verification Code (Eq. Contract Spec. Iss. HY para. 3.8) Verification Method
(QPP Iss. A) NDRA Applicable Items
(QPP Iss. A) LRI Spec. Para. N LRI Spec. Para. Title Compliance/Non Complicance/Marginality Documentary evidence of Compliance (Doc. Code, Paragraph number LRI std (P/n, S/n) supporting evidence Notes/ Evidence Deviation
(NCRs, waivers, ect.) Block 8 Pending actions
2.4.24 Electronic Components Selection Design Audit Design Documentation/Audit 2.4.24 Electronic Components Selection Compliant Design Audit
The Supplier (ED Consortium) maintains and updates the docs 1319-02319-37-4 " Eurodass Parts Management Plan", 1319-02267-37-4 " Eurodass Obsolescenze Management Plan" and 1319-0231837-4 " Eurodass Series Production Configuration Management Plan" .
According to the above documents Indra uses the following procedures which have been issued and recalled in BOM where applicable.
PEADs : CPRF-10001-MAC
Electrostatic Sensitive Device: DASS-10037-PFM
INDRA EFA DASS Conf Management Plan:STS0400DASS00-PCC
Failure Analysis Management: STS0400DASS00-MAI
Quality Plan for Electronic Components: DASS-10001-PAC
Screening of electronic components is performed at the appropriate assembling level (Module, sub-module, LRI), according to the attached list ofprocedures.
R3.3a
P/N EQP0632000070 S/N 0005. Also applicable to R3.3b SP EQP0632000073. Refer to report DASS-10021-RAC for justification.
2.4.24.1 Order of Preference N/A
2.4.24.2 Plastic Encapsulated Active Devices Design Audit Design Documentation/Audit Compliant Design Audit
ED Parts Management Plan 1319-02319-37-4 para. 11.2 covers procurement, storage, assembly and test of PEADS, They are based on standards J-STD-020 and J-STD-033.
There is a PEADS component used in the LRI. It is located inside a hermetically sealed box.
Refer to INDRA MDP;
LRI BOM 0632000070-LMA